TUFLOW Message 2070: Difference between revisions
Content deleted Content added
No edit summary |
No edit summary |
||
| (4 intermediate revisions by 2 users not shown) | |||
Line 3:
|alt_msg=ERROR 2070 - Same rainfall gauge applied to 2D cell more than once.
|type=[[ERROR]]
|message_desc=This ERROR message has two variations: one which states that more than one (different) rainfall gauges have been applied to a single cell, and the other which states that the same (duplicate) rainfall gauges have been applied to a single cell.
|suggestions= For the first "more than one rainfall gauges" ERROR, the message tells the user that overlapping RF polygons referencing '''different''' hyetographs has been assigned to an individual cell. This ERROR will be outputted if the .tcf command '''Rainfall Gauges''' has been set to '''One per Cell''' (as opposed to the default of '''Unlimited per Cell'''). Setting to '''One per Cell''' may be used as a quality control check to prevent duplication when spatially varying rainfall is used. If the duplication of rainfall is intentional (for example, the model uses one RF polygon to represent rainfall and another to represent infiltration) specify '''Unlimited per Cell''' to suppress the ERROR. <br>
<br>
For the second "same rainfall gauge" ERROR, the message tells the user that overlapping RF polygons referencing the '''same''' hyetograph has been assigned to an individual cell. The message is warning the user that the rainfall has been duplicated. In this scenario, setting <br><font color="blue"><tt>Rainfall Gauges </tt></font> <font color="red"><tt>==</tt></font><tt> Unlimited per Cell </tt>will not suppress the warning. Instead, the user must check for overlapping polygons and amend where necessary to remove the ERROR. Note that if the common boundary of two adjacent polygons falls on a cell centre (ZC point), this ERROR message may be outputted.
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
}}
| |||