TUFLOW Message 2110: Difference between revisions

Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=???? |message_desc=Material depth value for Mannings n value is negative. |suggestions=???? |discussion_page=* [[Talk:TUFLOW Message 2110|Discuss...'
 
No edit summary
 
(4 intermediate revisions by 3 users not shown)
Line 1:
{{TUFLOW_Message
|message_desctuflow_message=ERROR 2110 - Material depth value for Mannings n value is negative.
|tuflow_message=????
|alt_msg=NA
|message_desc=Material depth value for Mannings n value is negative.
|type=[[ERROR]]
|suggestions=????
|message_desc=Depth varying Manning's n curve has a depth value which is negative.
|discussion_page=* [[Talk:TUFLOW Message 2110|Discuss Message 2110]]
|suggestions=Remove negative depth from depth-Manning's n curve.
|link3=''
 
|link4=''
 
|prelink=[[TUFLOW_Message_2109|Message 2109]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2111|Message 2111]]
}}