Line 11:
The message switches from a CHECK to a WARNING at 0.3m (or 1 ft if using English Units) to draw further attention to large changes that may indicate potential erroneous inconsistency between the pit/channel level and the ZC ground level.<br>
|suggestions=Check elevation at 1D node and 2D cells, if a large discrepancy exists, review levels. For example a 1D pit with an elevation (from survey) maybe significantly below the elevation in the DEM. Using a SX connection with a Z flag will lower the cell centre to below the 1D level, but will not lower a flow-path into pit and may cause stability issues. To lower flow path into the pit, Z shape polygon can be used.
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
}}
| |||