Difference between revisions of "TUFLOW Message 2125"

From Tuflow
Jump to navigation Jump to search
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
|tuflow_message=ERROR 2125 - 2D domain "<font color="blue"><tt>Cell Side Wet/Dry Depth</tt></font>" is greater than the "<font color="blue"><tt>Cell Wet/Dry Depth</tt></font>".
+
|tuflow_message=ERROR 2125 - 2D domain "<font color="black"><tt>Cell Side Wet/Dry Depth</tt></font>" is greater than the "<font color="black"><tt>Cell Wet/Dry Depth</tt></font>".
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
 
|message_desc=2D domain <font color="blue"><tt>Cell Side Wet/Dry Depth</tt></font> is greater than the <font color="blue"><tt>Cell Wet/Dry Depth</tt></font>.
 
|message_desc=2D domain <font color="blue"><tt>Cell Side Wet/Dry Depth</tt></font> is greater than the <font color="blue"><tt>Cell Wet/Dry Depth</tt></font>.
 
|suggestions=As of Build 2008 08 AA, this command has been disabled and the cell side wet/dry depth is always set to half the Cell Wet/Dry Depth value. This was implemented to prevent mass errors that sometimes occurred due to inappropriate cell side wet/dry depths being used. Does not apply if Defaults == PRE 2008-08. The default value of 0.001m remains unchanged.  
 
|suggestions=As of Build 2008 08 AA, this command has been disabled and the cell side wet/dry depth is always set to half the Cell Wet/Dry Depth value. This was implemented to prevent mass errors that sometimes occurred due to inappropriate cell side wet/dry depths being used. Does not apply if Defaults == PRE 2008-08. The default value of 0.001m remains unchanged.  
|discussion_page=* [[Talk:TUFLOW Message 2125|Discuss Message 2125]]
+
 
|link3=''
+
 
|link4=''
 
|prelink=[[TUFLOW_Message_2124|Message 2124]]
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2126|Message 2126]]
 
 
}}
 
}}

Latest revision as of 15:00, 2 February 2023

TUFLOW Message
ERROR 2125 - 2D domain "Cell Side Wet/Dry Depth" is greater than the "Cell Wet/Dry Depth".

Alternate Message
NA

Message Type
ERROR

Description
2D domain Cell Side Wet/Dry Depth is greater than the Cell Wet/Dry Depth.

Suggestions
As of Build 2008 08 AA, this command has been disabled and the cell side wet/dry depth is always set to half the Cell Wet/Dry Depth value. This was implemented to prevent mass errors that sometimes occurred due to inappropriate cell side wet/dry depths being used. Does not apply if Defaults == PRE 2008-08. The default value of 0.001m remains unchanged.


Up
Go-up.png 2xxx Messages