Difference between revisions of "TUFLOW Message 2135"
Jump to navigation
Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=???? |message_desc=Following command must occur within a Start/End 2D Domain block. |suggestions=???? |discussion_page=* [[Talk:TUFLOW Message 21...') |
|||
(13 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{TUFLOW_Message | {{TUFLOW_Message | ||
− | |tuflow_message= | + | |tuflow_message=ERROR 2135 - Following command must occur within a Start/End 2D Domain block. |
− | + | |alt_msg=NA | |
− | | | + | |type=[[ERROR]] |
− | | | + | |message_desc=Must use <font color="blue"><tt>Start 2D Domain</tt></font> and <font color="blue"><tt>End 2D Domain</tt></font> commands to specify multiple 2D domains. The <u>mandatory</u> .tcf commands that occur within a 2D domain block are:<br> |
− | | | + | <font color="blue"><tt>BC Control File</tt></font> <br> |
− | + | <font color="blue"><tt>Geometry Control File </tt></font><br> | |
− | | | + | <font color="blue"><tt>Timestep </tt></font><br> |
− | | | + | <br> |
+ | <u>Optional</u> commands that can be used are:<br> | ||
+ | <font color="blue"><tt>Cell Wet/Dry Depth</tt></font><br> | ||
+ | <font color="blue"><tt>Cell Side Wet/Dry Depth</tt></font><br> | ||
+ | <font color="blue"><tt>Set IWL</tt></font><br> | ||
+ | <font color="blue"><tt>Read GIS FC</tt></font><br> | ||
+ | <font color="blue"><tt>Read GIS GLO</tt></font><br> | ||
+ | <font color="blue"><tt>Read GIS IWL</tt></font><br> | ||
+ | <font color="blue"><tt>Read MID IWL</tt></font><br> | ||
+ | <font color="blue"><tt>Read GIS LP</tt></font><br> | ||
+ | <font color="blue"><tt>Read GIS PO</tt></font><br> | ||
+ | <font color="blue"><tt>Instability Water Level</tt></font> <br> | ||
+ | |suggestions=For multiple 2D domain model listed command must occur within Start/End 2D Domain block. Move the command to a specifc 2D domain.<br><br> | ||
+ | |||
+ | For Example:<br> | ||
+ | [[File:ERROR 2135_002.JPG|500px]] | ||
+ | |||
+ | |||
+ | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
+ | |||
}} | }} |
Latest revision as of 13:38, 7 February 2023
TUFLOW Message
ERROR 2135 - Following command must occur within a Start/End 2D Domain block.
Alternate Message
NA
Message Type
ERROR
Description
Must use Start 2D Domain and End 2D Domain commands to specify multiple 2D domains. The mandatory .tcf commands that occur within a 2D domain block are:
BC Control File
Geometry Control File
Timestep
Optional commands that can be used are:
Cell Wet/Dry Depth
Cell Side Wet/Dry Depth
Set IWL
Read GIS FC
Read GIS GLO
Read GIS IWL
Read MID IWL
Read GIS LP
Read GIS PO
Instability Water Level
Suggestions
For multiple 2D domain model listed command must occur within Start/End 2D Domain block. Move the command to a specifc 2D domain.
Up |
---|
2xxx Messages |