Difference between revisions of "TUFLOW Message 2140"
Jump to navigation
Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=???? |message_desc=An error occurred reading the following line in the control file. |suggestions=???? |discussion_page=* [[Talk:TUFLOW Message 2...') |
|||
(8 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{TUFLOW_Message | {{TUFLOW_Message | ||
− | |tuflow_message= | + | |tuflow_message=ERROR 2140 - Reading following line in control file. |
+ | |alt_msg=NA | ||
+ | |type=[[ERROR]] | ||
|message_desc=An error occurred reading the following line in the control file. | |message_desc=An error occurred reading the following line in the control file. | ||
− | |suggestions= | + | |suggestions=Check the line is a valid TUFLOW command for the version of TUFLOW that you are running. Common mistake are:<br> |
− | + | * Omitting the double equals (<font color="blue"><tt>Set IWL </tt></font> <font color="red"><tt>=</tt></font><tt> 0.6</tt> not <font color="blue"><tt>Set IWL </tt></font> <font color="red"><tt>==</tt></font><tt> 0.6</tt>) | |
− | + | * Using the <font color="blue"><tt>Read GIS </tt></font> syntax for versions of TUFLOW prior to 2010 (use <font color="blue"><tt>Read MI </tt></font> instead). | |
− | + | * Using the <font color="blue"><tt>Read RowCol </tt></font> syntax for versions of TUFLOW prior to 2010 (use <font color="blue"><tt>Read MID </tt></font> instead). | |
− | | | + | * Putting a command in the wrong file, e.g. putting a geometry (.tgc) command in the boundary file (.tbc) |
− | + | ||
+ | |||
+ | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
+ | |||
}} | }} |
Latest revision as of 13:39, 7 February 2023
TUFLOW Message
ERROR 2140 - Reading following line in control file.
Alternate Message
NA
Message Type
ERROR
Description
An error occurred reading the following line in the control file.
Suggestions
Check the line is a valid TUFLOW command for the version of TUFLOW that you are running. Common mistake are:
- Omitting the double equals (Set IWL = 0.6 not Set IWL == 0.6)
- Using the Read GIS syntax for versions of TUFLOW prior to 2010 (use Read MI instead).
- Using the Read RowCol syntax for versions of TUFLOW prior to 2010 (use Read MID instead).
- Putting a command in the wrong file, e.g. putting a geometry (.tgc) command in the boundary file (.tbc)
Up |
---|