Difference between revisions of "TUFLOW Message 2306"
Jump to navigation
Jump to search
(2 intermediate revisions by the same user not shown) | |||
Line 3: | Line 3: | ||
|alt_msg=NA | |alt_msg=NA | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc=Occurs when a WrF (Weir calibration factor for upstream controlled weir flow) of zero has been found. For | + | |message_desc=Occurs when a WrF (Weir calibration factor for upstream controlled weir flow) of zero has been found. For <tt><font color="blue">Wetting and Drying </font><font color="red">== </font><font color="black">ON Method B</font></tt> which has been the default method since 2012-05 a non zero WrF must be specified. For <tt><font color="blue">Wetting and Drying </font><font color="red">== </font><font color="black">ON</font></tt> or <tt><font color="blue">Defaults </font><font color="red">== </font><font color="black">Pre 2012</font></tt> a zero value could be used to locally turn off the weir function. |
|suggestions=Check for zero values that may have been inadvertently applied using one or a combination of the following commands: <tt><font color="blue">Read GIS WrF </font><font color="red">==</font>, <font color="blue">Set WrF </font><font color="red">==</font>, <font color="blue">Read RowCol WrF </font><font color="red">==</font></tt>. | |suggestions=Check for zero values that may have been inadvertently applied using one or a combination of the following commands: <tt><font color="blue">Read GIS WrF </font><font color="red">==</font>, <font color="blue">Set WrF </font><font color="red">==</font>, <font color="blue">Read RowCol WrF </font><font color="red">==</font></tt>. | ||
− | + | ||
− | |||
− | |||
− | |||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 14:24, 7 February 2023
TUFLOW Message
ERROR 2306 - WrF value must be greater than zero.
Alternate Message
NA
Message Type
ERROR
Description
Occurs when a WrF (Weir calibration factor for upstream controlled weir flow) of zero has been found. For Wetting and Drying == ON Method B which has been the default method since 2012-05 a non zero WrF must be specified. For Wetting and Drying == ON or Defaults == Pre 2012 a zero value could be used to locally turn off the weir function.
Suggestions
Check for zero values that may have been inadvertently applied using one or a combination of the following commands: Read GIS WrF ==, Set WrF ==, Read RowCol WrF ==.
Up |
---|
2xxx Messages |