|suggestions=Check for zero values that may have been inadvertently applied using one or a combination of the following commands: <tt><font color="blue">Read GIS WrF </font><font color="red">==</font>, <font color="blue">Set WrF </font><font color="red">==</font>, <font color="blue">Read RowCol WrF </font><font color="red">==</font></tt>.
 
|suggestions=Check for zero values that may have been inadvertently applied using one or a combination of the following commands: <tt><font color="blue">Read GIS WrF </font><font color="red">==</font>, <font color="blue">Set WrF </font><font color="red">==</font>, <font color="blue">Read RowCol WrF </font><font color="red">==</font></tt>.
  
|prelink=[[TUFLOW_Message_2305|Message 2305]]
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2308|Message 2308]]
 
 
}}
 
}}

Latest revision as of 14:24, 7 February 2023

TUFLOW Message
ERROR 2306 - WrF value must be greater than zero.

Alternate Message
NA

Message Type
ERROR

Description
Occurs when a WrF (Weir calibration factor for upstream controlled weir flow) of zero has been found. For Wetting and Drying == ON Method B which has been the default method since 2012-05 a non zero WrF must be specified. For Wetting and Drying == ON or Defaults == Pre 2012 a zero value could be used to locally turn off the weir function.

Suggestions
Check for zero values that may have been inadvertently applied using one or a combination of the following commands: Read GIS WrF ==, Set WrF ==, Read RowCol WrF ==.