TUFLOW Message
WARNING 2415 - Too many regions for writing TIN files.
Alternate Message
ERROR 2415 - Too many regions for writing TIN files. Please contact support@tuflow.com.
Description
Pre 2011-09, TUFLOW would stop with an ERROR 2415 if more than 10,000 regions to be TINned in a Read GIS Shape command when using XF files and/or specified within the WRITE TIN option. As of Build 2011-09-AE, TUFLOW continues without writing anymore XF files or TINs for the remaining regions and outputs a WARNING 2415.