|tuflow_message=CHECK 3520 - Found SGS cell face that has minimum Face elevation lower than the minimum cell centre elevations on both sides.
|alt_msg=CHECK 3520 - Minimum U elevation must be higher than the minimum cell centre elevations on both sides in SGS. ZCmin left = "a", ZUmin = "b", ZCmin right = "c"<br>
|alt_msg=NA
CHECK 3520 - Minimum V elevation must be higher than the minimum cell centre elevations on both sides in SGS. ZCmin left = "a", ZUmin = "b", ZCmin right = "c"
|type=[[CHECK]]
|message_desc=SGS cellmodel faceneeds hasto minimuminsure Faceevery cell face elevation is NOT lower than the minimum cell centre elevations on both sides. The warning suggest discontinuity in sub-grid elevation, which can happen occasionally during pre-processing of Sub-Grid Sampling. If this happens, the cell face elevation will be increased automatically to insure simulation stability.
|suggestions=Although TUFLOW automatically correct the face elevations, users can turn <font color="blue"><tt>SGS Face Elevation Warning</tt></font> <font color="red"><tt>==</tt></font> <tt>ON</tt> (the default is "<tt>OFF</tt>") to report every faces with the issue to the _message_p layer. If the geometries input layers are all correctly set around these faces, turn <font color="blue"><tt>SGS Face Elevation Warning</tt></font> <font color="red"><tt>==</tt></font> <tt>OFF</tt> to omit this warning message.