Difference between revisions of "1D Integrity Tool - Pipe Direction"
Jump to navigation
Jump to search
Ellis Symons (talk | contribs) |
|||
(One intermediate revision by one other user not shown) | |||
Line 14: | Line 14: | ||
The following options are available: | The following options are available: | ||
<ul> | <ul> | ||
− | <li>Based on inverts - will change the pipe direction if there is an adverse gradient (downstream invert is higher than the upstream invert). Recommended only if it is apparent from an initial, manual inspection that the pipe dataset has occurrences of this error (i.e. not recommended to run this option by default without first confirming it's needed).<br><br> | + | <li>'''Based on inverts''' - will change the pipe direction if there is an adverse gradient (downstream invert is higher than the upstream invert). Recommended only if it is apparent from an initial, manual inspection that the pipe dataset has occurrences of this error (i.e. not recommended to run this option by default without first confirming it's needed).<br><br> |
''Note:<br>This option will only correct pipe direction if the adverse inverts are in the channel attribute data (i.e. if elevations are stored at the pits, then this option will not change the pipe direction).''<br><Br> | ''Note:<br>This option will only correct pipe direction if the adverse inverts are in the channel attribute data (i.e. if elevations are stored at the pits, then this option will not change the pipe direction).''<br><Br> | ||
− | <li>Based on pipe direction continuity - This option will perform a basic check based on the incoming and outgoing pipe directions. If the | + | <li>'''Based on pipe direction continuity''' - This option will perform a basic check based on the incoming and outgoing pipe directions. If the upstream or downstream junction has 3 or more pipes entering/leaving, the tool will not change the pipe direction as the continuity at these locations can be ambiguous. |
</ul> | </ul> | ||
<Br> | <Br> |
Latest revision as of 12:07, 6 March 2023
Tool Description
Checks pipe direction and will correct based on the selected processing option.
Inputs
The following inputs are used:
- Input Network Lines
Outputs
The following are output from the tool:
- Output point layer - an output log from the tool documenting where pipe directions were reversed.
- A temporary layer for each input with pipe direction corrected.
Processing Options
The following options are available:
- Based on inverts - will change the pipe direction if there is an adverse gradient (downstream invert is higher than the upstream invert). Recommended only if it is apparent from an initial, manual inspection that the pipe dataset has occurrences of this error (i.e. not recommended to run this option by default without first confirming it's needed).
Note:
This option will only correct pipe direction if the adverse inverts are in the channel attribute data (i.e. if elevations are stored at the pits, then this option will not change the pipe direction).
- Based on pipe direction continuity - This option will perform a basic check based on the incoming and outgoing pipe directions. If the upstream or downstream junction has 3 or more pipes entering/leaving, the tool will not change the pipe direction as the continuity at these locations can be ambiguous.
Prior to TUFLOW Plugin Version 3.3 the tool allowed both processing options to be run together, however it has been changed so that each processing option should be run separately and sequentially.'
Up |
---|
Back to 1D Integrity Tool Main Page |