Difference between revisions of "TUFLOW Message 1125"

From Tuflow
Jump to navigation Jump to search
Line 6: Line 6:
 
|type=[[WARNING]]
 
|type=[[WARNING]]
 
|message_desc=For a pump channel the depth values should start at 0 and the flow values should finish with zero flow.
 
|message_desc=For a pump channel the depth values should start at 0 and the flow values should finish with zero flow.
|suggestions=Review the pump flow curve for the channel.
+
|suggestions=Review the pump flow curve for the channel. The maximum head, difference between upstream and downstream invert, should have zero flow assigned.
  
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
}}
 
}}

Revision as of 17:44, 24 August 2023

TUFLOW Message
WARNING 1125 - yQ curve <curve name> for Pump <channel ID> does not start at zero depth and/or does not finish with zero flow.
First Depth-Flow Values = <depth value, flow value>
Last Depth-Flow Values = <depth value, flow value>

Alternate Message
NA

Message Type
WARNING

Description
For a pump channel the depth values should start at 0 and the flow values should finish with zero flow.

Suggestions
Review the pump flow curve for the channel. The maximum head, difference between upstream and downstream invert, should have zero flow assigned.


Up
Go-up.png 1xxx Messages