Difference between revisions of "TUFLOW Message 1125"

From Tuflow
Jump to navigation Jump to search
(Created page with "{{TUFLOW_Message |tuflow_message=WARNING 1125 - yQ curve <curve name> for Pump <channel ID> does not start at zero depth and/or does not finish with zero flow.<br> First Depth...")
 
 
(5 intermediate revisions by 3 users not shown)
Line 5: Line 5:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[WARNING]]
 
|type=[[WARNING]]
|message_desc=For a pump channel the depth values should start at 0 and the flow values should with zero flow.
+
|message_desc=For a pump channel the depth vs discharge curve represents the downstream head vs pump discharge curve. The first row should specify the discharge at zero (0) downstream head (i.e. start at zero depth), and the last row should specify the maximum downstream head that the pump can work against (i.e. finish with zero flow).
|suggestions=Review the pump flow curve for the channel.
+
|suggestions=Review the pump flow curve for the channel. The maximum head, difference between upstream and downstream invert, should have zero flow assigned.
|discussion_page=* [[Talk:TUFLOW Message 1124|Discuss Message 1124]]
+
 
|link3=''
 
|link4=''
 
|prelink=[[TUFLOW_Message_1123|Message 1123]]
 
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1125|Message 1125]]
 
 
}}
 
}}

Latest revision as of 14:42, 12 February 2024

TUFLOW Message
WARNING 1125 - yQ curve <curve name> for Pump <channel ID> does not start at zero depth and/or does not finish with zero flow.
First Depth-Flow Values = <depth value, flow value>
Last Depth-Flow Values = <depth value, flow value>

Alternate Message
NA

Message Type
WARNING

Description
For a pump channel the depth vs discharge curve represents the downstream head vs pump discharge curve. The first row should specify the discharge at zero (0) downstream head (i.e. start at zero depth), and the last row should specify the maximum downstream head that the pump can work against (i.e. finish with zero flow).

Suggestions
Review the pump flow curve for the channel. The maximum head, difference between upstream and downstream invert, should have zero flow assigned.


Up
Go-up.png 1xxx Messages