Latest revision as of 11:37, 15 March 2024
TUFLOW Message
ERROR 2065 - Unresolvable connections to 1D Nodes: "a"
Alternate Message
ERROR 2065 - [QPC] Unresolvable connections to 1D Nodes: "a"
Message Type
ERROR
Description
This error can occur when two CN lines are snapped to the same HX vertex.
Suggestions
Create additional vertex on the HX line and snap one of the CN lines to this vertex instead.
| Up |
|---|