Difference between revisions of "TUFLOW Message 2025"
Jump to navigation
Jump to search
Line 4: | Line 4: | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
|message_desc=Incompatible Flags set for 1D/2D Interface (2D HX) boundary. | |message_desc=Incompatible Flags set for 1D/2D Interface (2D HX) boundary. | ||
− | |suggestions= | + | |suggestions=Valid flags for a HX type boundary are outlined in Table 4.33 [2D Boundary Conditions (2d_bc) Attribute Descriptions] in the 2010 TUFLOW manual. Ensure that only valid flags are used. |
|discussion_page=* [[Talk:TUFLOW Message 2025|Discuss Message 2025]] | |discussion_page=* [[Talk:TUFLOW Message 2025|Discuss Message 2025]] | ||
|link3='' | |link3='' |
Revision as of 13:07, 3 July 2012
TUFLOW Message
ERROR 2025 - Incompatible Flags set for 2D HX boundary.
Alternate Message
NA
Message Type
ERROR
Description
Incompatible Flags set for 1D/2D Interface (2D HX) boundary.
Suggestions
Valid flags for a HX type boundary are outlined in Table 4.33 [2D Boundary Conditions (2d_bc) Attribute Descriptions] in the 2010 TUFLOW manual. Ensure that only valid flags are used.