TUFLOW Message 2210: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
 
Line 3: Line 3:
|alt_msg=NA
|alt_msg=NA
|type=[[CHECK]]
|type=[[CHECK]]
|message_desc=For layered Flow Constriction (2d_lfcsh) object the obvert of the lowest layer (e.g. soffit of bridge deck) is below ground level.
|message_desc=For layered Flow Constriction (2d_lfcsh) and bridge (2d_bg) object the obvert of the lowest layer (e.g. soffit of bridge deck) is below ground level.
|suggestions=Check inverts associated with layered flow constriction.
|suggestions=Check inverts associated with bridge and layered flow constriction.


|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]

Latest revision as of 13:27, 11 April 2024

TUFLOW Message
CHECK 2210 - Top of first FC Layer is below ground level.

Alternate Message
NA

Message Type
CHECK

Description
For layered Flow Constriction (2d_lfcsh) and bridge (2d_bg) object the obvert of the lowest layer (e.g. soffit of bridge deck) is below ground level.

Suggestions
Check inverts associated with bridge and layered flow constriction.


Up