TUFLOW Message 2215: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
No edit summary |
||
| (2 intermediate revisions by one other user not shown) | |||
| Line 4: | Line 4: | ||
|type=[[WARNING]] |
|type=[[WARNING]] |
||
|message_desc=A 1D pit object can be connected to a maximum of 10 2D cells. |
|message_desc=A 1D pit object can be connected to a maximum of 10 2D cells. |
||
|suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer. |
|suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer. |
||
|discussion_page=* [[Talk:TUFLOW Message 2215|Discuss Message 2215]] |
|||
If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit. To use this approach, the 1d_nwk "Q" pit will need to be set up as a line rather than a point. |
|||
|link3='' |
|||
|link4='' |
|||
|prelink=[[TUFLOW_Message_2214|Message 2214]] |
|||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] |
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] |
||
|nextlink=[[TUFLOW_Message_2216|Message 2216]] |
|||
}} |
}} |
||
Latest revision as of 20:36, 26 June 2024
TUFLOW Message
WARNING 2215 - Exceeded limit of 2D cells connected to 1D pit object.
Alternate Message
NA
Message Type
WARNING
Description
A 1D pit object can be connected to a maximum of 10 2D cells.
Suggestions
Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer.
If a very large pit object is modelled which requires connection to more 2D cell than the maximum a SX boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit. To use this approach, the 1d_nwk "Q" pit will need to be set up as a line rather than a point.
| Up |
|---|