Difference between revisions of "TUFLOW Message 2215"

From Tuflow
Jump to navigation Jump to search
 
Line 4: Line 4:
 
|type=[[WARNING]]
 
|type=[[WARNING]]
 
|message_desc=A 1D pit object can be connected to a maximum of 10 2D cells.
 
|message_desc=A 1D pit object can be connected to a maximum of 10 2D cells.
|suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer.  If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit.
+
|suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer.   
 +
 
 +
If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit. To use this approach, the 1d_nwk "Q" pit will need to be set up as a line rather than a point.  
  
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
}}
 
}}

Latest revision as of 20:36, 26 June 2024

TUFLOW Message
WARNING 2215 - Exceeded limit of 2D cells connected to 1D pit object.

Alternate Message
NA

Message Type
WARNING

Description
A 1D pit object can be connected to a maximum of 10 2D cells.

Suggestions
Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer.

If a very large pit object is modelled which requires connection to more 2D cell than the maximum a SX boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit. To use this approach, the 1d_nwk "Q" pit will need to be set up as a line rather than a point.


Up
Go-up.png 2xxx Messages