TUFLOW Message 2215: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=WARNING 2215 - Exceeded limit of 2D cells connected to 1D pit object. |alt_msg=NA |type=WARNING |message_desc=???? |suggestions=???? |discuss...'
 
No edit summary
 
(4 intermediate revisions by 3 users not shown)
Line 3: Line 3:
|alt_msg=NA
|alt_msg=NA
|type=[[WARNING]]
|type=[[WARNING]]
|message_desc=A 1D pit object can be connected to a maximum of 10 2D cells.
|message_desc=????
|suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer.
|suggestions=????

|discussion_page=* [[Talk:TUFLOW Message 2215|Discuss Message 2215]]
If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit. To use this approach, the 1d_nwk "Q" pit will need to be set up as a line rather than a point.
|link3=''

|link4=''
|prelink=[[TUFLOW_Message_2214|Message 2214]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2216|Message 2216]]
}}
}}

Latest revision as of 20:36, 26 June 2024

TUFLOW Message
WARNING 2215 - Exceeded limit of 2D cells connected to 1D pit object.

Alternate Message
NA

Message Type
WARNING

Description
A 1D pit object can be connected to a maximum of 10 2D cells.

Suggestions
Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer.

If a very large pit object is modelled which requires connection to more 2D cell than the maximum a SX boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit. To use this approach, the 1d_nwk "Q" pit will need to be set up as a line rather than a point.


Up
2xxx Messages