Difference between revisions of "Check Files 1d x1d nodes"
Jump to navigation
Jump to search
Steph.dufour (talk | contribs) |
|||
(3 intermediate revisions by one other user not shown) | |||
Line 15: | Line 15: | ||
| ID_DS||The ID of the external 1D node immediately downstream. | | ID_DS||The ID of the external 1D node immediately downstream. | ||
|- | |- | ||
− | | X1D_Index|| | + | | X1D_Index||Index ID of nodes within an external 1D scheme. |
|- | |- | ||
| Bed_Level||The bed level of the external ID Node. For Flood Modeller, this value is the bed level of the node minus the depth of the Preissmann slot if used (by default this is 1m). | | Bed_Level||The bed level of the external ID Node. For Flood Modeller, this value is the bed level of the node minus the depth of the Preissmann slot if used (by default this is 1m). | ||
Line 21: | Line 21: | ||
| Spill_Level||xxxxx. | | Spill_Level||xxxxx. | ||
|- | |- | ||
− | | Junction_Type|| | + | | Junction_Type||Sequential numbering of all nodes connected to a JUNCTION unit in Flood Modeller. |
|- | |- | ||
− | | Unit_Type|| | + | | Unit_Type||An ID denoting the type of unit in the external 1D scheme connected to TUFLOW. For Flood Modeller, these are: <br> |
+ | 0 - RIVER unit with a chainage downstream of 0m <br> | ||
+ | 2 - HTBDY <br> | ||
+ | 10 - WEIR unit <br> | ||
+ | 11 - BERNOULLI loss unit <br> | ||
+ | 18 - RNWEIR unit <br> | ||
+ | 19 - RIVER unit <br> | ||
+ | 20 - SPILL unit <br> | ||
+ | 21 - SLUICE unit <br> | ||
+ | 42 - ORIFICE unit <br> | ||
+ | 43 - USBPR bridge unit <br> | ||
+ | 55 - NCBDY <br> | ||
|} | |} | ||
− | [[TUFLOW_Check_Files| | + | |
+ | {{Tips Navigation | ||
+ | |uplink=[[TUFLOW_Check_Files | TUFLOW Check Files]] | ||
+ | }} |
Latest revision as of 15:33, 19 August 2024
The x1d_nodes check file contains information on nodes read in from an external 1D domain such as Flood Modeller (previously known as ISIS), XP-SWMM and 12D Solutions DDA 1D solution. It is useful for cross-checking these external 1D nodes and associated information passed from these 1D schemes.
The following check files may also be of use for models that use external 1D domains:
Attributes of _x1d_nodes check
Attribute Name | Attribute Description |
---|---|
ID | The ID of the external 1D node. |
ID_DS | The ID of the external 1D node immediately downstream. |
X1D_Index | Index ID of nodes within an external 1D scheme. |
Bed_Level | The bed level of the external ID Node. For Flood Modeller, this value is the bed level of the node minus the depth of the Preissmann slot if used (by default this is 1m). |
Spill_Level | xxxxx. |
Junction_Type | Sequential numbering of all nodes connected to a JUNCTION unit in Flood Modeller. |
Unit_Type | An ID denoting the type of unit in the external 1D scheme connected to TUFLOW. For Flood Modeller, these are: 0 - RIVER unit with a chainage downstream of 0m |
Up |
---|
TUFLOW Check Files |