Difference between revisions of "TUFLOW Message 2221"

From Tuflow
Jump to navigation Jump to search
 
(One intermediate revision by one other user not shown)
Line 3: Line 3:
 
|alt_msg=ERROR 2221 - Insufficient number of attributes for 2d_hx (2d_bc) layer. <br> ERROR 2221 - Insufficient number of attributes for 2d_lfcsh layer. <br> ERROR 2221 - Insufficient number of attributes for 2d_vzsh layer. <br> ERROR 2221 - Insufficient number of attributes for 2d_zrsh layer. <br> ERROR 2221 - Insufficient number of attributes for 2d_zsh layer.
 
|alt_msg=ERROR 2221 - Insufficient number of attributes for 2d_hx (2d_bc) layer. <br> ERROR 2221 - Insufficient number of attributes for 2d_lfcsh layer. <br> ERROR 2221 - Insufficient number of attributes for 2d_vzsh layer. <br> ERROR 2221 - Insufficient number of attributes for 2d_zrsh layer. <br> ERROR 2221 - Insufficient number of attributes for 2d_zsh layer.
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=Layer has insufficient attributes for the specified layer type.  For example a 2d_fcsh layer should have the attributes listed in Table 4.19 of the 2010 TUFLOW manual.
+
|message_desc=Layer has insufficient attributes for the specified layer type.  Refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for the required attributes for the specified layer type.
 
|suggestions=Ensure layer has correct attributes as defined by the TUFLOW manual or the empty (template) files created by TUFLOW with the <font color="blue"><tt>Write Empty MI Files </tt></font><font color="red"><tt>== </tt></font> .tcf command.
 
|suggestions=Ensure layer has correct attributes as defined by the TUFLOW manual or the empty (template) files created by TUFLOW with the <font color="blue"><tt>Write Empty MI Files </tt></font><font color="red"><tt>== </tt></font> .tcf command.
  
|prelink=[[TUFLOW_Message_2220|Message 2220]]
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2222|Message 2222]]
 
 
}}
 
}}

Latest revision as of 08:52, 23 September 2024

TUFLOW Message
ERROR 2221 - Insufficient number of attributes for 2d_fcsh layer.

Alternate Message
ERROR 2221 - Insufficient number of attributes for 2d_hx (2d_bc) layer.
ERROR 2221 - Insufficient number of attributes for 2d_lfcsh layer.
ERROR 2221 - Insufficient number of attributes for 2d_vzsh layer.
ERROR 2221 - Insufficient number of attributes for 2d_zrsh layer.
ERROR 2221 - Insufficient number of attributes for 2d_zsh layer.

Message Type
ERROR

Description
Layer has insufficient attributes for the specified layer type. Refer to the TUFLOW Manual for the required attributes for the specified layer type.

Suggestions
Ensure layer has correct attributes as defined by the TUFLOW manual or the empty (template) files created by TUFLOW with the Write Empty MI Files == .tcf command.


Up
Go-up.png 2xxx Messages