Difference between revisions of "TUFLOW Message 2131"

From Tuflow
Jump to navigation Jump to search
 
(4 intermediate revisions by one other user not shown)
Line 4: Line 4:
 
|type=[[ERROR]]
 
|type=[[ERROR]]
 
|message_desc=Reading parameter(s) or option for .tcf command below, or command is ambiguous.
 
|message_desc=Reading parameter(s) or option for .tcf command below, or command is ambiguous.
|suggestions=Check command is a valid TUFLOW command as per Appendix A of TUFLOW manual and that the double equal (==) is used as opposed to a single =.  For example use <br>  <font color="green"><tt>BC Control File == </tt></font> <u> NOT </u><font color="green"><tt>BC Control File = </tt></font>.<br>
+
|suggestions=Check command is a valid TUFLOW command listed in the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> and that the double equal (<font color="red"><tt>==</tt></font>) is used as opposed to a single =.  For example use <br>  <font color="blue"><tt>BC Control File </tt></font><font color="red"><tt>== </tt></font> <u> NOT </u><font color="blue"><tt>BC Control File </tt></font><font color="red"><tt>= </tt></font>.<br>
This error message also shows when newer commands are used in older versions of TUFLOW in which they haven't been available yet, e.g. using "Solution Scheme == HPC" in TUFLOW versions prior to 2017.
+
This error message also shows when newer commands are used in older versions of TUFLOW in which they haven't been available yet, e.g. using <font color="blue"><tt>Solution Scheme </tt></font><font color="red"><tt>== </tt></font><font color="black"><tt>HPC</tt></font> in TUFLOW versions prior to 2017.
|discussion_page=* [[Talk:TUFLOW Message 2131|Discuss Message 2131]]
+
 
|link3=''
+
 
|link4=''
 
|prelink=[[TUFLOW_Message_2130|Message 2130]]
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2132|Message 2132]]
+
 
 
}}
 
}}

Latest revision as of 08:56, 23 September 2024

TUFLOW Message
ERROR 2131 - Reading parameter(s) or option for .tcf command below, or command is ambiguous.

Alternate Message
NA

Message Type
ERROR

Description
Reading parameter(s) or option for .tcf command below, or command is ambiguous.

Suggestions
Check command is a valid TUFLOW command listed in the TUFLOW Manual and that the double equal (==) is used as opposed to a single =. For example use
BC Control File == NOT BC Control File = .
This error message also shows when newer commands are used in older versions of TUFLOW in which they haven't been available yet, e.g. using Solution Scheme == HPC in TUFLOW versions prior to 2017.


Up