Difference between revisions of "TUFLOW Message 1025"

From Tuflow
Jump to navigation Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1025 - Number of bridge channels and BG tables not the same. |alt_msg=ERROR 1025 - Number of culvert channels and CV details not the same. ...')
 
 
(3 intermediate revisions by 2 users not shown)
Line 3: Line 3:
 
|alt_msg=ERROR 1025 - Number of culvert channels and CV details not the same. <br> ERROR 1025 - Number of variable geometry channels and VG tables not the same. <br> ERROR 1025 - Number of weir channels and WR details not the same.
 
|alt_msg=ERROR 1025 - Number of culvert channels and CV details not the same. <br> ERROR 1025 - Number of variable geometry channels and VG tables not the same. <br> ERROR 1025 - Number of weir channels and WR details not the same.
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=????
+
|message_desc=Bridge structures are modelled using a height varying form loss coefficient rather than fixed contraction and expansion losses.  A table (referred to as a BG Table) of backwater or form loss coefficient versus height is required for each bridge channel.  BG Tables can be entered using .csv files via a 1d_tab (often renamed as 1d_bg) layer (see <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u>).<br>
|suggestions=????
+
Where the loss coefficient is constant through to the bridge deck (eg. no losses such as a clear spanning bridge, or pier losses only), the BG table can automatically be created by specifying a positive non-zero value for the Form_or_Bend_Loss attribute in the 1d_nwk layer (see <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u>).  Also note the use of this attribute in applying additional losses to a BG table.<br>
|discussion_page=* [[Talk:TUFLOW Message 1025|Discuss Message 1025]]
+
As of 2010 TUFLOW build, fixed field format inputs are no longer supported. Prior to build 2010, these losses could be applied in fixed field format.
|link3=''
+
|suggestions=Ensure that each bridge channel has a BG table specified either via a 1d_tab layer, or via a fixed coefficient in the 1d_nwk layer. Check that fixed field losses are not being used, as these may be ignored in later versions of TUFLOW.
|link4=''
+
<br>
|prelink=[[TUFLOW_Message_1024|Message 1024]]
+
 
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1026|Message 1026]]
 
 
}}
 
}}

Latest revision as of 09:19, 23 September 2024

TUFLOW Message
ERROR 1025 - Number of bridge channels and BG tables not the same.

Alternate Message
ERROR 1025 - Number of culvert channels and CV details not the same.
ERROR 1025 - Number of variable geometry channels and VG tables not the same.
ERROR 1025 - Number of weir channels and WR details not the same.

Message Type
ERROR

Description
Bridge structures are modelled using a height varying form loss coefficient rather than fixed contraction and expansion losses. A table (referred to as a BG Table) of backwater or form loss coefficient versus height is required for each bridge channel. BG Tables can be entered using .csv files via a 1d_tab (often renamed as 1d_bg) layer (see TUFLOW Manual).
Where the loss coefficient is constant through to the bridge deck (eg. no losses such as a clear spanning bridge, or pier losses only), the BG table can automatically be created by specifying a positive non-zero value for the Form_or_Bend_Loss attribute in the 1d_nwk layer (see TUFLOW Manual). Also note the use of this attribute in applying additional losses to a BG table.
As of 2010 TUFLOW build, fixed field format inputs are no longer supported. Prior to build 2010, these losses could be applied in fixed field format.

Suggestions
Ensure that each bridge channel has a BG table specified either via a 1d_tab layer, or via a fixed coefficient in the 1d_nwk layer. Check that fixed field losses are not being used, as these may be ignored in later versions of TUFLOW.