TUFLOW Message 2816: Difference between revisions
Created page with "{{TUFLOW_Message |tuflow_message=ERROR 2816 - |alt_msg=NA<br> |type=ERROR |message_desc= |suggestions= |prelink=Message 2815 |uplink=2xxx_TUFL..." |
No edit summary |
||
(6 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{TUFLOW_Message |
{{TUFLOW_Message |
||
|tuflow_message=ERROR 2816 - |
|tuflow_message=ERROR 2816 - Unable to read integer value from "<font color="blue"><tt>Set Code</tt></font>" line. |
||
|alt_msg=NA<br> |
|||
|alt_msg=ERROR 2816 - Unable to read code value from "<font color="blue"><tt>Read GIS Code BC </tt></font> <font color="red"><tt>==</tt></font>" polygon when processing Quadtree mesh.<br> |
|||
ERROR 2816 - Unable to read code value from "<font color="blue"><tt>Read GIS Code </tt></font> <font color="red"><tt>==</tt></font>" polygon when processing Quadtree mesh.<br> |
|||
ERROR 2816 - Unable to read IWL value after "<font color="blue"><tt>Set IWL </tt></font> <font color="red"><tt>==</tt></font>".<br> |
|||
ERROR 2816 - Unable to read IWL value.<br> |
|||
|type=[[ERROR]] |
|type=[[ERROR]] |
||
|message_desc= |
|message_desc=TUFLOW is unable to read the input. |
||
|suggestions=Check that the input is correct. For example "<font color="blue"><tt>Set IWL </tt></font> <font color="red"><tt>==</tt></font>" is expecting an integer value and ERROR 2816 may be produced if you are reading in an input later (e.g. 2d_iwl_R.shp) which instead should be read in using the "<font color="blue"><tt>Read GIS IWL</tt></font> <font color="red"><tt>==</tt></font>" command. <br> |
|||
|suggestions= |
|||
Refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for more information. |
|||
|prelink=[[TUFLOW_Message_2815|Message 2815]] |
|||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] |
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] |
||
|nextlink=[[TUFLOW_Message_2817|Message 2817]] |
|||
}} |
}} |
Latest revision as of 09:36, 23 September 2024
TUFLOW Message
ERROR 2816 - Unable to read integer value from "Set Code" line.
Alternate Message
ERROR 2816 - Unable to read code value from "Read GIS Code BC ==" polygon when processing Quadtree mesh.
ERROR 2816 - Unable to read code value from "Read GIS Code ==" polygon when processing Quadtree mesh.
ERROR 2816 - Unable to read IWL value after "Set IWL ==".
ERROR 2816 - Unable to read IWL value.
Message Type
ERROR
Description
TUFLOW is unable to read the input.
Suggestions
Check that the input is correct. For example "Set IWL ==" is expecting an integer value and ERROR 2816 may be produced if you are reading in an input later (e.g. 2d_iwl_R.shp) which instead should be read in using the "Read GIS IWL ==" command.
Refer to the TUFLOW Manual for more information.
Up |
---|
![]() |