Difference between revisions of "TUFLOW Message 1056"

From Tuflow
Jump to navigation Jump to search
 
(4 intermediate revisions by 2 users not shown)
Line 3: Line 3:
 
|alt_msg=ERROR 1056 - Incompatible flags "F" and "N" specified for CS data ",a," in ",a,
 
|alt_msg=ERROR 1056 - Incompatible flags "F" and "N" specified for CS data ",a," in ",a,
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc='''"E"''' and '''"T"''' are flow area flags for XZ type cross-sections (see ecf command "Flow Area" in TUFLOW manual for more details). Specify an '''“E”''' to use effective area or a '''“T”''' to use total area when calculating the flow area.  If neither is specified, the global value set using "Flow Area ==" is used, the default flow area method is effective. <br>
+
|message_desc='''"E"''' and '''"T"''' are flow area flags for XZ type cross-sections (see ecf command "Flow Area" in <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for more details). Specify an '''“E”''' to use effective area or a '''“T”''' to use total area when calculating the flow area.  If neither is specified, the global value set using "<font color="blue"><tt>Flow Area </tt></font><font color="red"><tt>==</tt></font>" is used, the default flow area method is effective. <br>
 
<br>
 
<br>
'''"F"''' and '''"N"''' are vertical change in resistance for CS or HW type cross-sections.  The '''one''' of the following should be specified:<br>
+
'''"F"''' and '''"N"''' are vertical change in resistance for CS or HW type cross-sections.  Only '''''one''''' of the following should be specified:<br>
 
'''“F”''' for a multiplication factor; or<br>
 
'''“F”''' for a multiplication factor; or<br>
 
'''“N”''' for a Manning’s n value.   
 
'''“N”''' for a Manning’s n value.   
|suggestions=Specify only one of either an "E" or a "T" for flow area flags or "F" or "N" for vertically varying resistance flags.
+
|suggestions=Specify only '''''one''''' of either an "E" or a "T" for flow area flags or "F" or "N" for vertically varying resistance flags.
|discussion_page=* [[Talk:TUFLOW Message 1056|Discuss Message 1056]]
+
 
|link3=''
+
 
|link4=''
 
|prelink=[[TUFLOW_Message_1055|Message 1055]]
 
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1057|Message 1057]]
 
 
}}
 
}}

Latest revision as of 09:55, 23 September 2024

TUFLOW Message
ERROR 1056 - Incompatible flags "E" and "T" specified for cross-section ",a," in ",a,

Alternate Message
ERROR 1056 - Incompatible flags "F" and "N" specified for CS data ",a," in ",a,

Message Type
ERROR

Description
"E" and "T" are flow area flags for XZ type cross-sections (see ecf command "Flow Area" in TUFLOW Manual for more details). Specify an “E” to use effective area or a “T” to use total area when calculating the flow area. If neither is specified, the global value set using "Flow Area ==" is used, the default flow area method is effective.

"F" and "N" are vertical change in resistance for CS or HW type cross-sections. Only one of the following should be specified:
“F” for a multiplication factor; or
“N” for a Manning’s n value.

Suggestions
Specify only one of either an "E" or a "T" for flow area flags or "F" or "N" for vertically varying resistance flags.


Up
Go-up.png 1xxx Messages