Difference between revisions of "TUFLOW Message 0100"
(Created page with '{{TUFLOW_Message |tuflow_message=ERROR 0100 - A "BC DATABASE" command must occur before a "READ BC" command |alt_msg=NA |type=ERROR |message_desc=???? |suggestions=???? |disc...') |
|||
(8 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{TUFLOW_Message | {{TUFLOW_Message | ||
− | |tuflow_message=ERROR 0100 - A "BC | + | |tuflow_message=ERROR 0100 - A "<font color="blue"><tt>BC Database</tt></font>" command must occur before a "<font color="blue"><tt>Read BC</tt></font>" command |
|alt_msg=NA | |alt_msg=NA | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc= | + | |message_desc=A <font color="blue"><tt>BC Database </tt></font>command must occur prior to any 1D (.ecf) and 2D (.tbc) <font color="blue"><tt>Read GIS BC </tt></font>command(s). |
− | + | ||
− | + | The reason for this is that <font color="blue"><tt>BC Database </tt></font> can be specified any number of times, with the most recent occurrence being used to set the active database when a <font color="blue"><tt>Read GIS BC </tt></font> command occurs. This was used by modellers as a way of applying different events or probabilities to different boundaries. If using the 2010-10 release or later, it is recommended to switch to the new event management feature as this is much more flexible and intuitive (refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u>).<br> | |
− | | | + | This error can occur if bc_dbase is listed under a scenario/event block, but incorrect scenario/event is specified and the simulation runs without bc_dbase. |
− | + | |suggestions=Check the <font color="blue"><tt>BC Database </tt></font>command occurs before any <font color="blue"><tt>Read GIS BC </tt></font> commands. If there is no <font color="blue"><tt>BC Database </tt></font>command one will need to be specified (unless there are no boundaries, ie. no <font color="blue"><tt>Read GIS BC </tt></font> commands). | |
− | + | <br> | |
+ | |||
|uplink=[[0xxx_TUFLOW_Messages|0xxx Messages]] | |uplink=[[0xxx_TUFLOW_Messages|0xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 09:58, 23 September 2024
TUFLOW Message
ERROR 0100 - A "BC Database" command must occur before a "Read BC" command
Alternate Message
NA
Message Type
ERROR
Description
A BC Database command must occur prior to any 1D (.ecf) and 2D (.tbc) Read GIS BC command(s).
The reason for this is that BC Database can be specified any number of times, with the most recent occurrence being used to set the active database when a Read GIS BC command occurs. This was used by modellers as a way of applying different events or probabilities to different boundaries. If using the 2010-10 release or later, it is recommended to switch to the new event management feature as this is much more flexible and intuitive (refer to the TUFLOW Manual).
This error can occur if bc_dbase is listed under a scenario/event block, but incorrect scenario/event is specified and the simulation runs without bc_dbase.
Suggestions
Check the BC Database command occurs before any Read GIS BC commands. If there is no BC Database command one will need to be specified (unless there are no boundaries, ie. no Read GIS BC commands).
Up |
---|
0xxx Messages |