Check Files 1d pit A: Difference between revisions

Content deleted Content added
No edit summary
No edit summary
 
(8 intermediate revisions by 3 users not shown)
Line 9:
| ID||The pit ID.
|-
| Type||The pit type, see TUFLOWthe <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for a list of pit types.<br>
For example a "Q" stands Q pit, while a "Q(VPI)" type is a Virtual Pipe Inlet.
|-
| VP_Network_ID||Used Virtual Pipe Network ID (as an integer) used to determine which outlet(s) the flow into the inlet pits discharges from.
|-
| Inlet_Type||For a VPI or Q pit, the name of a pit inlet type in the Pit Inlet Database. Not used for other pits.
|-
| VP_Sur_Index||Only used for VPI pits if using the HPC solver. In the event that the total flow into the VPIs on the same VP_Network_ID exceeds the maximum outflow capacity of the VPOs of that VP_Network_ID (see Qmax below), one or more of the VPI flow rates must be modified. The surcharge index is used to determine how VPI flows are adjusted. The VPIs with the lowest surcharge index are given priority.
|-
| VP_QMax||Only used for VPI and VPO if using the HPC solver:. For VPOs the maximum flow that can discharge back into the 2D domain. ForVPIsFor VPIs the maximum surcharge capacity or flow back on to the 2D domain. To prevent a VPI from surcharging enter a QMax of 0.0 (zero).
|-
| Width||For C pits the diameter of the pit cross-section in the vertical plane. For R and W pits, the width of the pit section in the vertical plane. For all pits the width is used to determine the number of 2D cells to connect.
|-
| Conn_2D||Used to control the connection type. For pits this field must be blank or set to “SX”. If set to blank, is treated as a SX connection. Other options maybe provided in the future.
|-
| Conn_No||Overwrite the automatically determined number of connected 2D cells.
Line 28 ⟶ 29:
|-
| Number_of||The number of pits.
|-
| Lag_Approach||Sets the lag approach. <br>
*'''None''' or blank: No lag is applied.
*'''Shift''': Shift method applied.
*'''Decay''': Decay method applied.
|-
| Lag_Value||Lag value in hours.
|-
| Invert||The elevation from the 2D cell the pit connects to or that entered via a 1d_nwk layer.
Line 33 ⟶ 41:
| Q_factor||This is the multiplication factor applied to the discharge to allow for any blockage and/or if Number_of pits is greater than 1.
|-
| i_1d_layer||The integer index of the GIS layer that the pit came from. For example an '''i_1d_layer'''i_1d_nwk value of 4 would be the 4th input layer (1d_nwk_M08_pits_001) below.<br>
<font color="blue"><tt>Read GIS NetworkPits </tt></font> <font color="red"><tt>==</tt></font><tt> mi\1d_nwk_M04_channels_001.MIF1d_nwk_M04_pits_001_P</tt><br>
<font color="blue"><tt>Read GIS NetworkPits </tt></font> <font color="red"><tt>==</tt></font><tt> mi\1d_nwk_M05_bridge_001.MIF1d_nwk_M05_pits_001_P</tt><br>
<font color="blue"><tt>Read GIS NetworkPits </tt></font> <font color="red"><tt>==</tt></font><tt> mi\1d_nwk_M07_trunk_998.MIF1d_nwk_M07_pits_998_P</tt><br>
<font color="blue"><tt>Read GIS NetworkPits </tt></font> <font color="red"><tt>==</tt></font><tt> mi\1d_nwk_M08_pits_001.MIF1d_nwk_M08_pits_001_P</tt>
 
|}
 
 