Check Files 1d pit A: Difference between revisions

Content deleted Content added
No edit summary
No edit summary
 
(4 intermediate revisions by 2 users not shown)
Line 9:
| ID||The pit ID.
|-
| Type||The pit type, see TUFLOWthe <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for a list of pit types.<br>
For example a "Q" stands Q pit, while a "Q(VPI)" type is a Virtual Pipe Inlet.
|-
| VP_Network_ID||Used Virtual Pipe Network ID (as an integer) used to determine which outlet(s) the flow into the inlet pits discharges from.
|-
| Inlet_Type||For a VPI or Q pit, the name of a pit inlet type in the Pit Inlet Database. Not used for other pits.
Line 28 ⟶ 29:
|-
| Number_of||The number of pits.
|-
| Lag_Approach||Sets the lag approach. <br>
*'''None''' or blank: No lag is applied.
*'''Shift''': Shift method applied.
*'''Decay''': Decay method applied.
|-
| Lag_Value||Lag value in hours.
|-
| Invert||The elevation from the 2D cell the pit connects to or that entered via a 1d_nwk layer.
Line 33 ⟶ 41:
| Q_factor||This is the multiplication factor applied to the discharge to allow for any blockage and/or if Number_of pits is greater than 1.
|-
| i_1d_layer||The integer index of the GIS layer that the pit came from. For example an '''i_1d_layer'''i_1d_nwk value of 4 would be the 4th input layer (1d_nwk_M08_pits_001) below.<br>
<font color="blue"><tt>Read GIS Pits </tt></font> <font color="red"><tt>==</tt></font><tt> mi\1d_nwk_M04_pits_001.MIF1d_nwk_M04_pits_001_P</tt><br>
<font color="blue"><tt>Read GIS Pits </tt></font> <font color="red"><tt>==</tt></font><tt> mi\1d_nwk_M05_pits_001.MIF1d_nwk_M05_pits_001_P</tt><br>
<font color="blue"><tt>Read GIS Pits </tt></font> <font color="red"><tt>==</tt></font><tt> mi\1d_nwk_M07_pits_998.MIF1d_nwk_M07_pits_998_P</tt><br>
<font color="blue"><tt>Read GIS Pits </tt></font> <font color="red"><tt>==</tt></font><tt> mi\1d_nwk_M08_pits_001.MIF1d_nwk_M08_pits_001_P</tt>
 
|}
 
 
{{Tips Navigation
|uplink=[[TUFLOW_Check_Files | TUFLOW Check Files]]
}}