TUFLOW Message 2467: Difference between revisions

Content deleted Content added
No edit summary
No edit summary
Line 1:
{{TUFLOW_Message
|tuflow_message=CHECKERROR 2467 - Overlapping Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZV point.
|alt_msg=CHECKERROR 2467 - Overlapping Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZU point.<br>
ERRORCHECK 2467 - Overlapping Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZUZV point.<br>
ERRORCHECK 2467 - Overlapping Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZVZU point.
|type=[[CHECKERROR]]<br>[[ERROR]]
[[CHECK]]
|message_desc=A cell side encountered overlapping flow constrictions.
|suggestions=From 2023 release, overlapping flow constriction triggers an error.<br> Modify the flow constriction shapes to avoid overlapping. If the overlap is intentional, use a different flow constriction combining parameters from the original flow constrictions. Refer to the <bru>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for more information.