|type=[[ERROR]]
|type=[[ERROR]]
|message_desc=Non-Newtonian mixing requires AD tracer for concentration.
|message_desc=Non-Newtonian mixing requires AD tracer for concentration.
|suggestions=A passive tracer must be included to utilise non-Newtonian mixing in a model. Refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for further information on advection-dispersion (AD) setup.
|suggestions=Please contact [mailto:support@tuflow.com support@tuflow.com].


|prelink=[[TUFLOW_Message_2486|Message 2486]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2488|Message 2488]]
}}
}}

Latest revision as of 12:43, 7 October 2024

TUFLOW Message
ERROR 2487 - Non-Newtonian mixing requires AD tracer for concentration.

Alternate Message
NA

Message Type
ERROR

Description
Non-Newtonian mixing requires AD tracer for concentration.

Suggestions
A passive tracer must be included to utilise non-Newtonian mixing in a model. Refer to the TUFLOW Manual for further information on advection-dispersion (AD) setup.