TUFLOW Message 2825: Difference between revisions
Content deleted Content added
No edit summary |
No edit summary |
||
| (2 intermediate revisions by 2 users not shown) | |||
Line 1:
{{TUFLOW_Message
|tuflow_message=WARNING 2825 - More than one level one nesting polygon found. Will only use one polygon with nesting level of 1. Overriding previously processed polygon.
|alt_msg=
|type=[[WARNING]]
|message_desc=More than one level one nesting polygons are found. The last level 1 nesting polygon read by TUFLOW will override any level 1 nesting polygons processed previously.
|suggestions=Check the nesting levels of the polygons and make sure the level 1 nesting polygon is specified correctly. Note that level 1 nesting polygon is NOT required if the model origin and extent are defined in the
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
}}
| |||