| |type=[[ERROR]] | |type=[[ERROR]] | ||
| |message_desc=Invalid SGS ZH Sample Ratio. This value is used to control the area used for SGS at ZH locations and it should be between 0 and 1. The area is set to <tt><''ratio''> X ''cell_area''</tt> to sample and generate Z values around a cell corner (the sampled elevations are not used in the hydraulic computations, only for map output).  | |||
| |message_desc=Invalid SGS ZH SAMPLE RATIO. This value should be 0 ~ 1. | |||
| |suggestions=Ensure the .tgc command "<tt><font color="blue">SGS ZH Sample Ratio</font><font color="red"> ==</font></tt>" is set to a value between 0 and 1.  | |||
| |suggestions=Please contact [mailto:support@tuflow.com support@tuflow.com]. | |||
| |uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]] | |uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]] | ||
Latest revision as of 11:24, 12 November 2024
TUFLOW Message 
ERROR 3509 - Invalid SGS ZH SAMPLE RATIO. This value should be 0 ~ 1.
Alternate Message 
NA
Message Type 
ERROR
Description 
Invalid SGS ZH Sample Ratio. This value is used to control the area used for SGS at ZH locations and it should be between 0 and 1. The area is set to <ratio> X cell_area to sample and generate Z values around a cell corner (the sampled elevations are not used in the hydraulic computations, only for map output).
Suggestions 
Ensure the .tgc command "SGS ZH Sample Ratio ==" is set to a value between 0 and 1.