TUFLOW Message 3548: Difference between revisions
Content deleted Content added
No edit summary |
No edit summary |
||
| (3 intermediate revisions by the same user not shown) | |||
Line 1:
{{TUFLOW_Message
|tuflow_message=CHECK 3548 - Setting SGS Sample Distance Target to minimum grid zpt resolution of "
|alt_msg=NA<br>
|type=[[CHECK]]
|message_desc=Setting SGS Sample Distance Target to minimum grid zpt resolution of "<>". The .tcf commands "<tt><font color="blue">SGS Sample Target Distance </font><font color="red">==</font></tt>" and "<tt><font color="blue">SGS Sample Frequency </font><font color="red">==</font></tt>" were not defined. Therefore, a scan of the .tgc is performed to find the minimum raster grid resolution used in the "<tt><font color="blue">Read Grid Zpt</font><font color="red"> ==</font></tt>" command(s), and this is used as the sampling target distance to compute the sampling frequency.
|suggestions=If needed, use the .tcf commands "<tt><font color="blue">SGS Sample Target Distance </font><font color="red">==</font></tt>" and/or "<tt><font color="blue">SGS Sample Frequency </font><font color="red">==</font></tt>" to manually set the SGS sampling target distance.<br>
Please refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for more information.
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]]
| |||