TUFLOW Message 1070: Difference between revisions
Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1070 - Cross-section with effective area must have a relative resistance of 1 in primary sub-section. |alt_msg=NA |type=ERROR |message_...' |
No edit summary |
||
| (2 intermediate revisions by one other user not shown) | |||
Line 3:
|alt_msg=NA
|type=[[ERROR]]
|message_desc=If using effective area, a relative resistance factor of 1.0 must occur at some point in the profile to indicate the primary sub-channel. If this is not included, grossly incorrect channel velocities can occur.
|suggestions=Update the cross-sections to indicate a primary sub-channel:
* In the 1D cross-section table link (1d_xs) layer, ensure at least one cross-section has the "Flag" attribute set to "'''R'''".
* Update the corresponding source table to contain a relative resistance factor of 1.0.
Refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for more information on cross-sections.
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
}}
| |||