TUFLOW Message 2042: Difference between revisions

Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=???? |message_desc=Cannot find or identify upstream ISIS unit node for 2D HX cell. Check for missing or unsnapped CN lines. |suggestions=???? |d...'
 
No edit summary
 
(8 intermediate revisions by 4 users not shown)
Line 1:
{{TUFLOW_Message
|tuflow_message=ERROR 2042 - Cannot find upstream Flood Modeller unit node for 2D HX cell.
|tuflow_message=????
|message_descalt_msg=ERROR 2042 - Cannot find or identify upstream ISIS unit node for 2D HX cell. Check for missing or unsnapped CN lines.
|type=[[ERROR]]
|suggestions=????
|message_desc=Cannot find or identify upstream Flood Modeller unit node for 2D HX cell.
|discussion_page=* [[Talk:TUFLOW Message 2042|Discuss Message 2042]]
|suggestions=Check for Flood Modeller nodes that have been digitised within a 1d_x1d_nodes GIS layer that are not snapped to CN lines. For example, the figure below shows node FC01.25a does not have any associated CN connection lines digitised within a 2d_bc layer. Digitise the CN lines to connect the Flood Modeller node to the 2D floodplain. <br>
|link3=''
<br>
|link4=''
[[File:Missing CN.PNG]]
|prelink=[[TUFLOW_Message_2041|Message 2041]]
 
|nextlink=[[TUFLOW_Message_2043|Message 2043]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
}}