Difference between revisions of "TUFLOW Message 2835"
Jump to navigation
Jump to search
(15 intermediate revisions by 5 users not shown) | |||
Line 1: | Line 1: | ||
{{TUFLOW_Message | {{TUFLOW_Message | ||
− | |tuflow_message=ERROR 2835 - Not expecting point for bc type: | + | |tuflow_message=ERROR 2835 - Not expecting point for bc type: "<>". |
− | |alt_msg= | + | |alt_msg=ERROR 2835 - Not expecting line for bc type: "<>".<br> |
+ | ERROR 2835 - Not expecting region for bc type: "<>".<br> | ||
+ | |||
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc= | + | |message_desc=Not expecting point / line / region for BC type: "<>". A point / line / region is not valid for the boundary condition (BC) type "<>". |
− | + | <br> | |
− | | | + | From the 2023-03 release, a point-type QT boundary is not supported when using TUFLOW Classic / HPC (bringing the behaviour in line with Quadtree). |
− | + | |suggestions=*Refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for information on the BC type "<>" and its specifications. | |
− | + | *If a QT point was intended to be used as an internal inflow boundary, transitioning to a 2d_sa setup is recommended. For an external boundary, the preferred approach is to use a 2d_bc QT line snapped to the code polygon. | |
− | + | ||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 17:15, 7 February 2025
TUFLOW Message
ERROR 2835 - Not expecting point for bc type: "<>".
Alternate Message
ERROR 2835 - Not expecting line for bc type: "<>".
ERROR 2835 - Not expecting region for bc type: "<>".
Message Type
ERROR
Description
Not expecting point / line / region for BC type: "<>". A point / line / region is not valid for the boundary condition (BC) type "<>".
From the 2023-03 release, a point-type QT boundary is not supported when using TUFLOW Classic / HPC (bringing the behaviour in line with Quadtree).
Suggestions
- Refer to the TUFLOW Manual for information on the BC type "<>" and its specifications.
- If a QT point was intended to be used as an internal inflow boundary, transitioning to a 2d_sa setup is recommended. For an external boundary, the preferred approach is to use a 2d_bc QT line snapped to the code polygon.
Up |
---|
![]() |