TUFLOW Message 2320: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
No edit summary |
||
(7 intermediate revisions by 3 users not shown) | |||
Line 4: | Line 4: | ||
ERROR 2320 - Read TGA command not yet supported in HPC or GPU solver.<br> |
ERROR 2320 - Read TGA command not yet supported in HPC or GPU solver.<br> |
||
ERROR 2320 - TUFLOW 2016-03 GPU Solver does not support 1D links.<br> |
ERROR 2320 - TUFLOW 2016-03 GPU Solver does not support 1D links.<br> |
||
ERROR 2320 - GLO commands not yet supported in HPC or GPU solver.<br> |
|||
ERROR 2320 - "Bed Resistance Values == CHEZY" not supported in HPC solver.<br> |
|||
ERROR 2320 - "Bed Resistance Values == MANNING M" not supported in HPC solver.<br> |
|||
WARNING 2320 - HPC or GPU Solver ignoring Read GIS Objects/Receptors commands.<br> |
WARNING 2320 - HPC or GPU Solver ignoring Read GIS Objects/Receptors commands.<br> |
||
... |
|||
|type=[[WARNING]]<br> |
|type=[[WARNING]]<br> |
||
[[ERROR]]<br> |
[[ERROR]]<br> |
||
|message_desc= Some TUFLOW Classic functionalities |
|message_desc= Some TUFLOW Classic functionalities are not supported by the TUFLOW HPC solver. |
||
|suggestions= |
|suggestions= |
||
* If using a 2d_fc layer, change to a 2d_lfcsh layer which is supported by TUFLOW HPC. |
|||
* The 2016-03 TUFLOW GPU solver is a legacy feature, TUFLOW HPC (on GPU hardware) should be used instead. |
|||
* GLO commands are supported in TUFLOW HPC from the 2023-03-AD build and onwards. |
|||
* Read GIS Objects/Receptors commands are supported in TUFLOW HPC from the 2023-03-AA build and onwards. |
|||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] |
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] |
Latest revision as of 16:03, 26 May 2025
TUFLOW Message
ERROR 2320 - FC commands not yet supported in HPC or GPU solver.
Alternate Message
ERROR 2320 - Read TGF command not yet supported in HPC or GPU solver.
ERROR 2320 - Read TGA command not yet supported in HPC or GPU solver.
ERROR 2320 - TUFLOW 2016-03 GPU Solver does not support 1D links.
ERROR 2320 - GLO commands not yet supported in HPC or GPU solver.
ERROR 2320 - "Bed Resistance Values == CHEZY" not supported in HPC solver.
ERROR 2320 - "Bed Resistance Values == MANNING M" not supported in HPC solver.
WARNING 2320 - HPC or GPU Solver ignoring Read GIS Objects/Receptors commands.
Description
Some TUFLOW Classic functionalities are not supported by the TUFLOW HPC solver.
Suggestions
- If using a 2d_fc layer, change to a 2d_lfcsh layer which is supported by TUFLOW HPC.
- The 2016-03 TUFLOW GPU solver is a legacy feature, TUFLOW HPC (on GPU hardware) should be used instead.
- GLO commands are supported in TUFLOW HPC from the 2023-03-AD build and onwards.
- Read GIS Objects/Receptors commands are supported in TUFLOW HPC from the 2023-03-AA build and onwards.
Up |
---|
![]() |