TUFLOW Message 2842: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
 
(One intermediate revision by one other user not shown)
Line 4: Line 4:


|type=[[ERROR]]
|type=[[ERROR]]
|message_desc=QPC [Cell id=<>, x=<>, y=<>] has no active cell connected.
|message_desc=A cell within Quadtree is isolated and has no active cell faces that connect to another cell.
|suggestions=Check the message_P.shp layer to find the isolated cell and reconfigure the 2d_code and 2d_bc layers to stop the particular cell from being isolated (or remove it).
|suggestions=Please contact [mailto:support@tuflow.com support@tuflow.com].


|prelink=[[TUFLOW_Message_2841|Message 2841]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2843|Message 2843]]
}}
}}

Latest revision as of 00:23, 28 May 2025

TUFLOW Message
ERROR 2842 - QPC [Cell id=<>, x=<>, y=<>] has no active cell connected.

Alternate Message
NA

Message Type
ERROR

Description
A cell within Quadtree is isolated and has no active cell faces that connect to another cell.

Suggestions
Check the message_P.shp layer to find the isolated cell and reconfigure the 2d_code and 2d_bc layers to stop the particular cell from being isolated (or remove it).


Up
2xxx Messages