TUFLOW Message 2246: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
Created page with "{{TUFLOW_Message |tuflow_message=ERROR 2246 - Weirs are not implemented for Chezy Coeffs. |alt_msg= |type=ERROR<br> |message_desc= Where flow in the 2D domain becomes upst..."
 
No edit summary
 
Line 1: Line 1:
{{TUFLOW_Message
{{TUFLOW_Message
|tuflow_message=ERROR 2246 - Weirs are not implemented for Chezy Coeffs.
|tuflow_message=ERROR 2246 - Weirs are not implemented for Chezy Coeffs.
|alt_msg=
|alt_msg=NA
|type=[[ERROR]]<br>
|type=[[ERROR]]<br>
|message_desc= Where flow in the 2D domain becomes upstream controlled, TUFLOW Classic automatically switches between either weir flow or upstream controlled friction flow. However, this feature cannot be used if the <tt><font color="blue">Bed Resistance Values</font></tt> is set to </font>CHEZY</tt>.
|message_desc= Where flow in the 2D domain becomes upstream controlled, TUFLOW Classic automatically switches between either weir flow or upstream controlled friction flow. However, this feature cannot be used if the <tt><font color="blue">Bed Resistance Values</font></tt> is set to </font>CHEZY</tt>.

Latest revision as of 11:43, 23 September 2025

TUFLOW Message
ERROR 2246 - Weirs are not implemented for Chezy Coeffs.

Alternate Message
NA

Message Type
ERROR

Description
Where flow in the 2D domain becomes upstream controlled, TUFLOW Classic automatically switches between either weir flow or upstream controlled friction flow. However, this feature cannot be used if the Bed Resistance Values is set to CHEZY.

Suggestions
Either use Bed Resistance Values == MANNING N, or switch off the weir flow by setting Free Overfall to ON WITHOUT WEIRS or OFF.


Up