TUFLOW Message 1391: Difference between revisions
No edit summary |
Anne.Kolega (talk | contribs) m i.e. |
||
| (One intermediate revision by one other user not shown) | |||
| Line 5: | Line 5: | ||
|message_desc=A TUFLOW 1D (ESTRY) node is trying to be connected to an external 1D scheme using a X1DH or X1DQ link as indicated in the message, but the TUFLOW node is already connected to an external 1D node using a link as indicated in the message. Only one external 1D scheme link can be specified for a TUFLOW (ESTRY) node. |
|message_desc=A TUFLOW 1D (ESTRY) node is trying to be connected to an external 1D scheme using a X1DH or X1DQ link as indicated in the message, but the TUFLOW node is already connected to an external 1D node using a link as indicated in the message. Only one external 1D scheme link can be specified for a TUFLOW (ESTRY) node. |
||
You can link two or more TUFLOW nodes to the same external 1D node by connecting the TUFLOW nodes ( |
You can link two or more TUFLOW nodes to the same external 1D node by connecting the TUFLOW nodes (i.e.. snap them or use a connector (X) channel), and link to the external node. |
||
|suggestions=Review connections to external 1D scheme for this node and remove the inappropriate one(s). |
|suggestions=Review connections to external 1D scheme for this node and remove the inappropriate one(s). |
||
|prelink=[[TUFLOW_Message_1382|Message 1382]] |
|||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
||
|nextlink=[[TUFLOW_Message_1392|Message 1392]] |
|||
}} |
}} |
||
Latest revision as of 11:34, 2 April 2026
TUFLOW Message
ERROR 1391 - Cannot connect Node with a X1DH or X1DQ link as the node is already connected to an external 1D domain via a X1DH or X1DQ link.
Alternate Message
NA
Message Type
ERROR
Description
A TUFLOW 1D (ESTRY) node is trying to be connected to an external 1D scheme using a X1DH or X1DQ link as indicated in the message, but the TUFLOW node is already connected to an external 1D node using a link as indicated in the message. Only one external 1D scheme link can be specified for a TUFLOW (ESTRY) node.
You can link two or more TUFLOW nodes to the same external 1D node by connecting the TUFLOW nodes (i.e.. snap them or use a connector (X) channel), and link to the external node.
Suggestions
Review connections to external 1D scheme for this node and remove the inappropriate one(s).
| Up |
|---|