Difference between revisions of "TUFLOW Message 2314"

From Tuflow
Jump to navigation Jump to search
(Created page with "{{TUFLOW_Message |tuflow_message=ERROR 2314 - Soil ID must be greater than 0 or less than 32767. Soil ID = 0. |alt_msg=NA |type=ERROR |message_desc= One or more cells wi...")
(No difference)

Revision as of 10:21, 22 October 2014

TUFLOW Message
ERROR 2314 - Soil ID must be greater than 0 or less than 32767. Soil ID = 0.

Alternate Message
NA

Message Type
ERROR

Description
One or more cells within the 2D domain have been assigned a Soil ID of '0'.

Suggestions
Carry out a check to ensure a Soil ID greater than 0 has been assigned to all objects within any 2d_soil layers. Alternatively, use the Set Soil command prior to any Read GIS Soil or Read GRID Soil commands in the tgc file to ensure all cells in the 2D domain have been assigned a soil type.


Up