Difference between revisions of "TUFLOW Message 1991"
Steph.dufour (talk | contribs) |
Steph.dufour (talk | contribs) |
||
Line 17: | Line 17: | ||
|link3='' | |link3='' | ||
|link4='' | |link4='' | ||
− | |prelink=[[ | + | |prelink=[[TUFLOW_Message_1527|Message 1527]] |
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
|nextlink=[[TUFLOW_Message_1998|Message 1998]] | |nextlink=[[TUFLOW_Message_1998|Message 1998]] | ||
}} | }} |
Revision as of 13:41, 2 February 2015
TUFLOW Message
WARNING 1991 - ",a,": Negative depth at Node ",a,": "," y =",f7.2," Bed =",f7.2," Iter =
Alternate Message
WARNING 1991 - ",a,": Negative depth at Node ",a,": "," y =",f7.2," Bed =",f7.2," dh =
Message Type
WARNING
Description
Numerical solution has resulted in a negative depth at 1D node. This indicates that the model is unstable or unhealthy in this area. There are a number of possible reason for this to occur, the most common are:
Incorrect bed levels upstream or downstream;
A large change in cross-sectional area;
Very steep channel entering a gently or advers grade channel;
Sudden change in flow area (for example a culvert width entered in mm not m, 1200 not 1.2);
Issues with 1D/2D linking (incorrect use of Z flag on culvert inlet / outlet);
To high a timestep; and
Low nodal area.
For a more detailed description on identify the start of instability please see Section 8.1.3 Tips for an Unhealthy 1D Domain and Section 8.1.4 Tips for Unhealthy 1D/2D Links of the TUFLOW manual (reference for 2010 version).
Suggestions
Identify start of instability and cause of instability and fix! See references above for guidance.
Up |
---|
1xxx Messages |