Difference between revisions of "TUFLOW Message 1522"

From Tuflow
Jump to navigation Jump to search
(Created page with "{{TUFLOW_Message |tuflow_message=CHECK 1522 - More than one culvert connected but could not create manhole at Node <Node ID> |alt_msg=NA |type=CHECK |message_desc=When app...")
 
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
|tuflow_message=CHECK 1522 - More than one culvert connected but could not create manhole at Node <Node ID>
+
|tuflow_message=ERROR 1522 - Unrecognised or unsupported operating control variable in line below, or invalid line
 +
|Operating Control Line = <variable name> == <dHUD / dH12>
 
|alt_msg=NA
 
|alt_msg=NA
|type=[[CHECK]]
+
|type=[[ERROR]]
 
|message_desc=When applying the Engelhund loss approach for manholes (see Section 4.5.2 of the 2010 TUFLOW manual), if an incoming culvert enters above the obvert of the highest outlet, the culvert is not included in the manhole loss calculations.  If there is only 1 incoming pipe with the invert above the obvert of the outlet culvert, the incoming culvert is ignored and with no inlet culvert to the node a manhole is not possible.  See also point 48(b) in the [http://www.tuflow.com/Download/TUFLOW/Releases/2012-05/Doc/TUFLOW%20Release%20Notes.2011-09%20and%202012-05.pdf release notes].
 
|message_desc=When applying the Engelhund loss approach for manholes (see Section 4.5.2 of the 2010 TUFLOW manual), if an incoming culvert enters above the obvert of the highest outlet, the culvert is not included in the manhole loss calculations.  If there is only 1 incoming pipe with the invert above the obvert of the outlet culvert, the incoming culvert is ignored and with no inlet culvert to the node a manhole is not possible.  See also point 48(b) in the [http://www.tuflow.com/Download/TUFLOW/Releases/2012-05/Doc/TUFLOW%20Release%20Notes.2011-09%20and%202012-05.pdf release notes].
 
|suggestions=Review the inverts on the culverts.  A point object in a "1d_mh" layer can be used to set the loss approach at each manhole.
 
|suggestions=Review the inverts on the culverts.  A point object in a "1d_mh" layer can be used to set the loss approach at each manhole.
|discussion_page=* [[Talk:TUFLOW Message 1402|Discuss Message 1402]]
+
|discussion_page=* [[Talk:TUFLOW Message 1522|Discuss Message 1522]]
 
|link3=''
 
|link3=''
 
|link4=''
 
|link4=''
|prelink=[[TUFLOW_Message_1401|Message 1401]]
+
|prelink=[[TUFLOW_Message_1510|Message 1510]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1510|Message 1510]]
+
|nextlink=[[TUFLOW_Message_1527|Message 1527]]
 
}}
 
}}

Revision as of 00:43, 19 June 2015

TUFLOW Message
ERROR 1522 - Unrecognised or unsupported operating control variable in line below, or invalid line

Alternate Message
NA

Message Type
ERROR

Description
When applying the Engelhund loss approach for manholes (see Section 4.5.2 of the 2010 TUFLOW manual), if an incoming culvert enters above the obvert of the highest outlet, the culvert is not included in the manhole loss calculations. If there is only 1 incoming pipe with the invert above the obvert of the outlet culvert, the incoming culvert is ignored and with no inlet culvert to the node a manhole is not possible. See also point 48(b) in the release notes.

Suggestions
Review the inverts on the culverts. A point object in a "1d_mh" layer can be used to set the loss approach at each manhole.


Up
Go-up.png 1xxx Messages