Difference between revisions of "TUFLOW Message 1048"
Jump to navigation
Jump to search
(Created page with "{{TUFLOW_Message |tuflow_message=WARNING 1048 - For B or W channel <Channel ID> ignoring Number_of attribute value which is greater than 1. |alt_msg=NA |type=WARNING |mess...") |
(No difference)
|
Revision as of 10:56, 14 August 2015
TUFLOW Message
WARNING 1048 - For B or W channel <Channel ID> ignoring Number_of attribute value which is greater than 1.
Alternate Message
NA
Message Type
WARNING
Description
The Number_of or No_of_Culverts attribute on the 1d_nwk file is not valid for bridge or weir channels. For the channel ID specified, a value of greater than 1 has been specified and is being ignored. For culverts this is the number of culvert barrels. For example a value of 3 would indicate three parallel culverts.
Suggestions
As this attribute is not used by TUFLOW for a bridge or weir type channel, for clarity it is recommended that the attribute be left at 0 or 1.
Up |
---|
![]() |