CHECK 1421 - Top level of bridge cross-section data differs to that in loss vs height table for channel <channel id>
Top level in HW table = <value>
Top level in LC table = <value>
Alternate Message
NA
Message Type
CHECK
Description
The highest elevation in the bridge cross-section data (the soffit) is different than the highest level in the bridge loss coefficient data.
Suggestions
Review the input data to ensure that the loss table and cross-section data is being input correctly.