Difference between revisions of "TUFLOW Message 2014"

From Tuflow
Jump to navigation Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=???? |message_desc=No active 2D cells within Source over Area (SA) inflow polygon. |suggestions=???? |discussion_page=* [[Talk:TUFLOW Message 201...')
 
 
(5 intermediate revisions by 3 users not shown)
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
|tuflow_message=????
+
|tuflow_message=ERROR 2014 - No active cells within SA inflow polygon.
|message_desc=No active 2D cells within Source over Area (SA) inflow polygon.
+
|alt_msg=NA
|suggestions=????
+
|type=[[ERROR]]
|discussion_page=* [[Talk:TUFLOW Message 2014|Discuss Message 2014]]
+
|message_desc=No active 2D cells within Source area (SA) inflow polygon.
|link3=''
+
|suggestions=Source area polygon is outside of active model code. Check SA polygon is in the correct location, active model area (2D code) may need to be extended. Check the code polygon has active cells (attribute of 1).
|link4=''
+
 
|prelink=[[TUFLOW_Message_2013|Message 2013]]
+
 
|nextlink=[[TUFLOW_Message_2015|Message 2015]]
+
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
}}
 
}}

Latest revision as of 10:55, 23 December 2022

TUFLOW Message
ERROR 2014 - No active cells within SA inflow polygon.

Alternate Message
NA

Message Type
ERROR

Description
No active 2D cells within Source area (SA) inflow polygon.

Suggestions
Source area polygon is outside of active model code. Check SA polygon is in the correct location, active model area (2D code) may need to be extended. Check the code polygon has active cells (attribute of 1).


Up
Go-up.png 2xxx Messages