Difference between revisions of "TUFLOW Message 1056"
(6 intermediate revisions by 2 users not shown) | |||
Line 3: | Line 3: | ||
|alt_msg=ERROR 1056 - Incompatible flags "F" and "N" specified for CS data ",a," in ",a, | |alt_msg=ERROR 1056 - Incompatible flags "F" and "N" specified for CS data ",a," in ",a, | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc='''"E"''' and '''"T"''' are flow area flags (see ecf command "Flow Area" in TUFLOW | + | |message_desc='''"E"''' and '''"T"''' are flow area flags for XZ type cross-sections (see ecf command "Flow Area" in <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for more details). Specify an '''“E”''' to use effective area or a '''“T”''' to use total area when calculating the flow area. If neither is specified, the global value set using "<font color="blue"><tt>Flow Area </tt></font><font color="red"><tt>==</tt></font>" is used, the default flow area method is effective. <br> |
− | + | <br> | |
− | + | '''"F"''' and '''"N"''' are vertical change in resistance for CS or HW type cross-sections. Only '''''one''''' of the following should be specified:<br> | |
− | + | '''“F”''' for a multiplication factor; or<br> | |
− | | | + | '''“N”''' for a Manning’s n value. |
− | + | |suggestions=Specify only '''''one''''' of either an "E" or a "T" for flow area flags or "F" or "N" for vertically varying resistance flags. | |
+ | |||
+ | |||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 09:55, 23 September 2024
TUFLOW Message
ERROR 1056 - Incompatible flags "E" and "T" specified for cross-section ",a," in ",a,
Alternate Message
ERROR 1056 - Incompatible flags "F" and "N" specified for CS data ",a," in ",a,
Message Type
ERROR
Description
"E" and "T" are flow area flags for XZ type cross-sections (see ecf command "Flow Area" in TUFLOW Manual for more details). Specify an “E” to use effective area or a “T” to use total area when calculating the flow area. If neither is specified, the global value set using "Flow Area ==" is used, the default flow area method is effective.
"F" and "N" are vertical change in resistance for CS or HW type cross-sections. Only one of the following should be specified:
“F” for a multiplication factor; or
“N” for a Manning’s n value.
Suggestions
Specify only one of either an "E" or a "T" for flow area flags or "F" or "N" for vertically varying resistance flags.
Up |
---|
1xxx Messages |