|message_desc=Invalid Manning's n value assigned to channel, this will occur for a 0 or negative Manning's n value.
|message_desc=Invalid Manning's n value assigned to channel, this will occur for a 0 or negative Manning's n value.
|suggestions=Assign a valid Manning's n value for channel. If material values are defined in the XZ cross-section ("M" flag), the n_or_n_F attribute in the 1d_nwk is a multiplication factor and should be set to 1 (this may be adjusted as part of the calibration process).
|suggestions=Assign a valid Manning's n value for channel. If material values are defined in the XZ cross-section ("M" flag), the n_or_n_F attribute in the 1d_nwk is a multiplication factor and should be set to 1 (this may be adjusted as part of the calibration process).

|discussion_page=* [[Talk:TUFLOW Message 1261|Discuss Message 1261]]

|link3=''
|link4=''
|prelink=[[TUFLOW_Message_1258|Message 1258]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1262|Message 1262]]
}}
}}

Latest revision as of 16:00, 22 December 2022

TUFLOW Message
ERROR 1261 - Invalid Manning's n value of ",a," assigned to channel

Alternate Message
NA

Message Type
ERROR

Description
Invalid Manning's n value assigned to channel, this will occur for a 0 or negative Manning's n value.

Suggestions
Assign a valid Manning's n value for channel. If material values are defined in the XZ cross-section ("M" flag), the n_or_n_F attribute in the 1d_nwk is a multiplication factor and should be set to 1 (this may be adjusted as part of the calibration process).