Difference between revisions of "TUFLOW Message 2014"
Jump to navigation
Jump to search
(3 intermediate revisions by 2 users not shown) | |||
Line 3: | Line 3: | ||
|alt_msg=NA | |alt_msg=NA | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc=No active 2D cells within Source | + | |message_desc=No active 2D cells within Source area (SA) inflow polygon. |
− | |suggestions=Source | + | |suggestions=Source area polygon is outside of active model code. Check SA polygon is in the correct location, active model area (2D code) may need to be extended. Check the code polygon has active cells (attribute of 1). |
− | + | ||
− | + | ||
− | |||
− | |||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 10:55, 23 December 2022
TUFLOW Message
ERROR 2014 - No active cells within SA inflow polygon.
Alternate Message
NA
Message Type
ERROR
Description
No active 2D cells within Source area (SA) inflow polygon.
Suggestions
Source area polygon is outside of active model code. Check SA polygon is in the correct location, active model area (2D code) may need to be extended. Check the code polygon has active cells (attribute of 1).
Up |
---|
2xxx Messages |