TUFLOW Message 1042: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
 
(One intermediate revision by the same user not shown)
Line 5: Line 5:
|message_desc=No upstream / downstream invert specified, TUFLOW is unable to interpolate an invert.
|message_desc=No upstream / downstream invert specified, TUFLOW is unable to interpolate an invert.
|suggestions=Specify inverts upstream and downstream of the culvert, either via the US_invert / DS_invert in the 1D channel object or via snapped 1D node objects.
|suggestions=Specify inverts upstream and downstream of the culvert, either via the US_invert / DS_invert in the 1D channel object or via snapped 1D node objects.

|discussion_page=* [[Talk:TUFLOW Message 1042|Discuss Message 1042]]
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_1041|Message 1041]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1043|Message 1043]]
}}
}}

Latest revision as of 14:26, 22 December 2022

TUFLOW Message
ERROR 1042 - Could not find a culvert invert downstream of culvert ",a,". Downstream invert not interpolated.

Alternate Message
ERROR 1042 - Could not find a culvert invert upstream of culvert ",a,". Upstream invert not interpolated.

Message Type
ERROR

Description
No upstream / downstream invert specified, TUFLOW is unable to interpolate an invert.

Suggestions
Specify inverts upstream and downstream of the culvert, either via the US_invert / DS_invert in the 1D channel object or via snapped 1D node objects.


Up
1xxx Messages